Description
IVPS 10KVA 48V Upgrade System Stronger Protection Built in BMS System Solar Inverter for Home Use
Felicity Solar IVPS Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment
PRODUCT ADVANTAGES
- Efficient power generation
Bypass Function
High Charging Current - Intelligent and friendly
Wide Range of AC input Voltage
Optional Electricity & Battery Priority - Safe and worry-free
20/60Hz Compatible
Intelligent Adjustment - Fast operation and maintenance
Overall Safety Design
Communicate with MPPT
SOLAR INVERTER IVPS SERIES
- Bypass charging function
- 90-280V Wide range of AC input voltage
- Grid electricity and battery power priority is optional
- 50/60Hz compatible
- Intelligently fine-tune the over-discharge voltage according to the load power
- Comprehensively upgraded safety protection design, industry-leading transformer over-temperature protection.
- Comprehensive scientific management of electric charging and solar charging, will soon get rid of MPPT exchange
IVPS Inverter SPECIFICATIONS
Model | IVPS2512 | IVPS2524 | IVPS3524 | IVPS3548 | IVPS5024 | IVPS5048 | IVPS7548 | IVPS10048 |
Rated Output Power(VA) | 2500VA | 2500VA | 3500VA | 3500VA | 5000VA | 5000VA | 7500VA | 10000VA |
Rated Output Power(W) | 2000W | 2000W | 2800W | 2800W | 4000W | 4000W | 6000W | 8000W |
Nominal DC Input Voltage | 12V | 24V | 48V | 24V | 48V | |||
Input Voltage Waveform | Sinusoidal(Utility or generator) | |||||||
Nominal Input Voltage | 220Vac | |||||||
Low Line Disconnect | 170±7Vac(UPS) 90±7Vac(APL) | |||||||
Low Line Re-connect AC Input Range |
180±7Vac(UPS) 100±7Vac(APL) | |||||||
High Line Disconnect | 280±7Vac | |||||||
High Line Re-connect | 270±7Vac | |||||||
Max AC Input Voltage | 280Vrms | |||||||
Nominal Input Frequency | 50Hz/60Hz | |||||||
Low Line Frequency Disconnect |
40±1Hz | |||||||
Low Line Frequency Re-connect |
42±1Hz | |||||||
High Line Frequency Disconnect |
65±1Hz | |||||||
High Line Frequency Re-connect |
63±1Hz | |||||||
Output Voltage Waveform | As same as input waveform | |||||||
Over-Load Protection(SMPS load) |
AC 30A | Air switch protection | ||||||
Output Short Circuit Protection |
AC 30A | Air switch protection | ||||||
Efficiency(Line mode) | ≥95% (Rated R load, and battery is fully charged) | |||||||
Transfer Time (AC to DC) | 15ms (typical) | |||||||
Transfer Time(DC toAC) | 15ms (typical) | |||||||
Pass Through Without Battery |
No | |||||||
Max Bypass Overload Current |
AC 30A | AC 63A | ||||||
Utility Charge Mode Specifications | ||||||||
Nominal Input Voltage | 220Vac | |||||||
Input Voltage Range | 90~280Vac | |||||||
Nominal Output Voltage | Dependent on battery type | |||||||
Max Charge Current | 40A | 50A | 60A | 80A | ||||
Charge Current Regulation | 0A~40A | 0A~50A | 0A~60A | 0A~80A | ||||
Battery Initial Voltage | Circuit breaker | |||||||
Charger Short Circuit | AC30A | AC 63A | ||||||
Breaker Size | Dependent on battery type or Self-defined | |||||||
Over Charge Protection | Yes |