IVPS 10KVA 48V Upgrade System Stronger protection Built in BMS System Solar Inverter for Home Use

Availability In Stock

Felicity Solar IVPS Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment
  • Widely Input Voltage: 90-280V AC
  • Nominal Input Voltage: 220V
  • Max. Charging Current: 80A

Description

IVPS 10KVA 48V Upgrade System Stronger Protection Built in BMS System Solar Inverter for Home Use

Felicity Solar IVPS Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment

PRODUCT ADVANTAGES

  • Efficient power generation
    Bypass Function
    High Charging Current
  • Intelligent and friendly
    Wide Range of AC input Voltage
    Optional Electricity & Battery Priority
  • Safe and worry-free
    20/60Hz Compatible
    Intelligent Adjustment
  • Fast operation and maintenance
    Overall Safety Design
    Communicate with MPPT

SOLAR INVERTER IVPS SERIES

  • Bypass charging function
  • 90-280V Wide range of AC input voltage
  • Grid electricity and battery power priority is optional
  • 50/60Hz compatible
  • Intelligently fine-tune the over-discharge voltage according to the load power
  • Comprehensively upgraded safety protection design, industry-leading transformer over-temperature protection.
  • Comprehensive scientific management of electric charging and solar charging, will soon get rid of MPPT exchange

 

IVPS Inverter SPECIFICATIONS
Model IVPS2512 IVPS2524 IVPS3524 IVPS3548 IVPS5024 IVPS5048 IVPS7548 IVPS10048
Rated Output Power(VA) 2500VA 2500VA 3500VA 3500VA 5000VA 5000VA 7500VA 10000VA
Rated Output Power(W) 2000W 2000W 2800W 2800W 4000W 4000W 6000W 8000W
Nominal DC Input Voltage 12V 24V 48V 24V 48V
Input Voltage Waveform Sinusoidal(Utility or generator)
Nominal Input Voltage 220Vac
Low Line Disconnect 170±7Vac(UPS) 90±7Vac(APL)
Low Line Re-connect
AC Input Range
180±7Vac(UPS) 100±7Vac(APL)
High Line Disconnect 280±7Vac
High Line Re-connect 270±7Vac
Max AC Input Voltage 280Vrms
Nominal Input Frequency 50Hz/60Hz
Low Line
Frequency Disconnect
40±1Hz
Low Line
Frequency Re-connect
42±1Hz
High Line
Frequency Disconnect
65±1Hz
High Line
Frequency Re-connect
63±1Hz
Output Voltage Waveform As same as input waveform
Over-Load
Protection(SMPS load)
AC 30A Air switch protection
Output Short
Circuit Protection
AC 30A Air switch protection
Efficiency(Line mode) ≥95% (Rated R load, and battery is fully charged)
Transfer Time (AC to DC) 15ms (typical)
Transfer Time(DC toAC) 15ms (typical)
Pass Through
Without Battery
No
Max Bypass
Overload Current
AC 30A AC 63A
Utility Charge Mode Specifications
Nominal Input Voltage 220Vac
Input Voltage Range 90~280Vac
Nominal Output Voltage Dependent on battery type
Max Charge Current 40A 50A 60A 80A
Charge Current Regulation 0A~40A 0A~50A 0A~60A 0A~80A
Battery Initial Voltage Circuit breaker
Charger Short Circuit AC30A AC 63A
Breaker Size Dependent on battery type or Self-defined
Over Charge Protection Yes
Back to Top

Search For Products

Product has been added to your cart