Description
IVPM 2.5KVA 24V Pure Sine Wave Inverter with 120A MPPT Solar Charge Controller Hybrid Inverter: Your Ultimate Solar Power Solution
Are you looking for a reliable and efficient power solution to maximize your solar energy usage? Look no further than the IVPM 2.5KVA 24V Pure Sine Wave Inverter with 120A MPPT Solar Charge Controller Hybrid Inverter. This advanced inverter is engineered to optimize solar power systems for residential or commercial use, providing you with uninterrupted power and greater energy savings.
The IVPM 2.5KVA inverter offers a true pure sine wave output, making it compatible with sensitive electronics and appliances, ensuring stable and clean energy that extends the lifespan of your devices. With a 120A MPPT solar charge controller built-in, the inverter can efficiently manage and maximize energy harvest from your solar panels, even in low-light conditions. The Maximum Power Point Tracking (MPPT) technology optimizes the voltage and current from your solar array, significantly increasing your system’s overall efficiency.
This hybrid inverter is designed to operate seamlessly between solar energy, battery backup, and grid power, making it a versatile solution for off-grid, grid-tied, or hybrid systems. Whether you’re looking to reduce your electricity bills, enjoy reliable power during outages, or adopt a sustainable energy lifestyle, this inverter is the perfect choice.
Built with durability and ease of installation in mind, the IVPM 2.5KVA inverter offers smart protection features, such as over-temperature protection, short-circuit protection, and overload protection, ensuring the longevity and safety of your system. The user-friendly LCD display keeps you informed about system performance, battery status, and solar power input at all times.
Investing in the IVPM 2.5KVA 24V Pure Sine Wave Inverter with 120A MPPT Solar Charge Controller Hybrid Inverter means investing in a future of clean, reliable, and cost-efficient energy.
Key Features:
- 2.5KVA Pure Sine Wave Output: Smooth, stable power for all types of appliances.
- 120A MPPT Solar Charge Controller: Maximize solar energy harvest and improve system efficiency.
- Hybrid System Compatibility: Seamlessly switches between solar, battery, and grid power.
- Advanced Protection: Built-in protections against overload, overheating, and short circuits.
- User-Friendly Display: Real-time monitoring of system performance and power usage.
Upgrade your solar power system today with the IVPM 2.5KVA 24V Pure Sine Wave Inverter with 120A MPPT Solar Charge Controller Hybrid Inverter and experience the future of energy independence.
Felicity Solar On/Off Grid Hybrid Inverter
Felicity Solar IVPM Low Frequency Solar Inverter With 120A MPPT Solar Inverter , Long Lifesan, Digital Screen and Stronger Protection. Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment
Model | IVPM2512 | IVPM2524 | IVPM3524 | IVPM3548 | IVPM5024 | IVPM5048 | IVPM7548 | IVPM10048 |
Rated Output Power(VA) | 2500VA | 2500VA | 3500VA | 3500VA | 5000VA | 5000VA | 7500VA | 10000VA |
Rated Output Power(W) | 2000W | 2000W | 2800W | 2800W | 4000W | 4000W | 6000W | 8000W |
Nominal DC Input Voltage | 12V | 24V | 48V | 24V | 48V | |||
Input Voltage Waveform | Sinusoidal(Utility or generator) | |||||||
Nominal Input Voltage | 220Vac | |||||||
Low Line Disconnect | 170±7Vac(UPS) 90±7Vac(APL) | |||||||
Low Line Re-connect AC Input Range |
180±7Vac(UPS) 100±7Vac(APL) | |||||||
High Line Disconnect | 280±7Vac | |||||||
High Line Re-connect | 270±7Vac | |||||||
Max AC Input Voltage | 280Vrms | |||||||
Nominal Input Frequency | 50Hz/60Hz | |||||||
Low Line Frequency Disconnect |
40±1Hz | |||||||
Low Line Frequency Re-connect |
42±1Hz | |||||||
High Line Frequency Disconnect |
65±1Hz | |||||||
High Line Frequency Re-connect |
63±1Hz | |||||||
Output Voltage Waveform | As same as input waveform | |||||||
Over-Load Protection(SMPS load) |
AC 30A | Air switch protection | ||||||
Output Short Circuit Protection |
AC 30A | Air switch protection | ||||||
Efficiency(Line mode) | ≥95% (Rated R load, and battery is fully charged) | |||||||
Transfer Time (AC to DC) | 15ms (typical) | |||||||
Transfer Time(DC toAC) | 15ms (typical) | |||||||
Pass Through Without Battery |
No | |||||||
Max Bypass Overload Current |
AC 30A | AC 63A | ||||||
Utility Charge Mode Specifications | ||||||||
Nominal Input Voltage | 220Vac | |||||||
Input Voltage Range | 90~280Vac | |||||||
Nominal Output Voltage | Dependent on battery type | |||||||
Max Charge Current | 40A | 50A | 60A | 80A | ||||
Charge Current Regulation | 0A~40A | 0A~50A | 0A~60A | 0A~80A | ||||
Battery Initial Voltage | Circuit breaker | |||||||
Charger Short Circuit | AC30A | AC 63A | ||||||
Breaker Size | Dependent on battery type or Self-defined | |||||||
Over Charge Protection | Yes |